PZH R2 PV/1000/40 MS

Kod: 7727058

PZH R2 PV/1000/40 MS

Kod: 7727058

PZH R2 PV are the lightning and surge arresters type 2 according to EN 61643-11 and IEC 61643-11 and UTE C 61-740-51. These arresters are recommended for use in the Lightning Protection Zones Concept at the boundaries of LPZ 1-2 (according to IEC EN 62305) for equipotential bonding of positive and negative busbars of photovoltaic systems and elimination of transient overvoltage that originates during the atmospheric discharges or switching processes. Particular varistor sectors, connected between the terminals L+, L- and PE, are equipped with internal disconnectors, which are activated when the varistors fail (overheat). Operational status indication of these disconnectors is partly visual (discoloration of the signal field) and partly remote monitoring (by potential free change over contacts - only MS types). The marking M specifies a type of construction with removable module.

Težina: 0.31

TEHNIČKI PODACI I STANDARDI

OZNAKE U KATALOGU


MATERIJALI


OZNAKA
MATERIJAL
Rf
nerđajući čelik
Rf*H4
kiselo otporni nerđajući čelik
Cu
bakar
Al
aluminijum
Fe
čelik
FeZn
pocinkovani čelik
FeZn-H
toplopocinkovani čelik
KFe
kaljeno jeklo
FeCu
pobakreno jeklo
Me
mesing
PE
polietilen – UV stabilan
N
najlon – UV stabilan
P-SV
poliester, ojačan staklenim vlaknom UV
pvc
elektrostatično plastificirano
PVC
otporna plastika
Les
les
Beton
beton
Ltž
liveni čelik
CuSn
kalajisani bakar
PP
polypropylen

DIMENZIJE PROVODNIKA

(pogodnost nosača za specifične profile provodnika)

OZNAKA
ZNAČENJE
Φ

prečnik okruglog provodnika

P

dimenzije preseka pljosnatog provodnika


SISTEM PRIČVRŠĆIVANJA PROVODNIKA NA NOSAČ

OZNAKA
ZNAČENJE
N

pričvršćivanje najlonskim pričvrsnim elementom

PE

pričvršćivanje sa polietilenskim pričvrsnim elementom

K
pričvršćivanje sa klik sistemom
V
pričvršćivanje sa vijcima
*
po porudžbini
Legenda oznaka

PZH R2 PV are the lightning and surge arresters type 2 according to EN 61643-11 and IEC 61643-11 and UTE C 61-740-51. These arresters are recommended for use in the Lightning Protection Zones Concept at the boundaries of LPZ 1-2 (according to IEC EN 62305) for equipotential bonding of positive and negative busbars of photovoltaic systems and elimination of transient overvoltage that originates during the atmospheric discharges or switching processes. Particular varistor sectors, connected between the terminals L+, L- and PE, are equipped with internal disconnectors, which are activated when the varistors fail (overheat). Operational status indication of these disconnectors is partly visual (discoloration of the signal field) and partly remote monitoring (by potential free change over contacts - only MS types). The marking M specifies a type of construction with removable module.